Achieve Fast Glycan Labelling and Analysis

N-glycosylation profiling of carbohydrates associated with therapeutic antibodies for faster development of biologics
Updated
Brought to you bySCIEX and Separation Science
Register for free to listen to this article
Listen with Speechify
0:00
2:00

SCIEX has produced an application note describing the N-glycosylation profiling of carbohydrates associated with therapeutic antibodies for faster, more cost-effective development of biologics.

SCIEX_fast_glycan_labelling.pngIntroduction
Glycan identification using traditional techniques is slow, requiring time- and labour-intensive sample preparation that can take a day or more. The goal of this application note was to demonstrate the advantages of the award-winning SCIEX fast glycan labelling and analysis technology for preparation and analysis of N-linked oligosaccharides.

Sample Preparation
Individual steps of the manual and automated approaches of the magnetic bead-mediated sample preparation protocol were performed using the SCIEX fast glycan labelling and analysis kit, which included three internal GU standards for instant, automated structural assignment.4 PNGase F was used for enzymatic release of the N-linked carbohydrates. This was followed by derivatization with a charged fluorophore (aminopyrene trisulfonate, APTS).

Results and Discussion
Results illustrate that by applying the Fast Glycan Labelling and Analysis Kit Assay for N-glycosylation analysis, sample preparation can be completed in as fast as 1 hour with excellent yield and a high level of reproducibility. Because the centrifugation steps during the sample preparation protocol are unnecessary, the process can be automated using liquid handling robots to provide a flexible and robust approach capable of reproducible sample processing.

Key Features

  • Complete sample preparation in about one hour with excellent yield and high reproducibility.
  • Magnetic bead clean-up reduces the presence of unbound dye, resulting in better characterization of complex sialylated structures.
  • Sample preparation procedure can be applied manually to a single sample or to as many as 96 samples at a time using automated liquid handling platforms.
  • A novel high-resolution gel buffer ensures excellent separation of target molecules.
  • 5 minute separations with automated, immediate glycan identification.
  • 32 Karat™ software automatically generates a report identifying all carbohydrate species with glycan image and monoisotopic mass information.