Combining Molecular Images Reveals Differences Within Diseased Tissues

Integrating mass spectrometry imaging, microscopy, and spatial transcriptomics helps researchers connect molecular distributions with local pathology.
Written byAimee Cichocki
Presented byAngela Kruse, PhD.
Visualization of multimodal mass spectrometry imaging of pancreatic islets

Google Flow 2026

Register for free to listen to this article
Listen with Speechify
0:00
3:00

Neighboring pancreatic islets can present different pathological features. In tissue from a donor with type 2 diabetes, one islet may contain an amyloid plaque while another nearby does not. Understanding that difference requires measurements that preserve their spatial context.

Angela Kruse, PhD., Assistant Professor at Ohio State University used this observation to introduce her research during a US HUPO webinar. She described work conducted with collaborators at Vanderbilt University and Delft University of Technology that combined molecular imaging techniques to investigate the environment surrounding amyloid deposits.

The study illustrates how complementary measurements can help researchers interpret tissue heterogeneity and identify molecular associations for further investigation.

Connecting Molecular Composition With Tissue Structure

Kruse’s investigation began with localized proteomic measurements of pancreatic islets with and without amyloid plaques. Differences in protein abundance raised questions about the surrounding tissue and the possible contribution of lipids and lipid-binding proteins to plaque formation.

Addressing those questions required several types of spatial information.

Working in analytical science?

Register for a FREE Separation Science account to subscribe to the Separation Science Newsletter.

Subscribe for free

The team combined spatial transcriptomics, multiplexed immunofluorescence, amyloid staining, and MALDI mass spectrometry imaging across two adjacent tissue sections. Each measurement contributed a different perspective: gene expression, protein markers, pathological features, or lipid distributions.

The multimodal workflow, described in a preprint, brings these measurements into a shared spatial framework. This integration allowed the researchers to examine which molecular signals occurred in particular tissue regions and how they related to the cells present.

Mapping lipid distributions adds information that can be difficult to infer from gene expression alone. In Kruse’s presentation, some lipid signals localized to islets, while others predominated in the surrounding exocrine tissue.

Checking What an Image Appears to Show

One example demonstrated the value of comparing modalities before assigning biological meaning.

Analysis of the spatial transcriptomics data identified regions with related gene-expression profiles. Some appeared round and approximately the size of islets, leading Kruse to expect that they represented islet tissue.

The protein-marker images showed otherwise. Those regions lacked the expected islet markers. Further analysis identified a different cellular composition, including Schwann cells, suggesting a neural–acinar niche.

Meanwhile, the actual islets separated into regions dominated by insulin-producing beta cells or glucagon-producing alpha cells.

The combined measurements therefore refined the tissue interpretation. Shape alone suggested one identity; molecular evidence supported another. Using the resulting regional classifications, the researchers applied interpretable machine learning to identify lipid signals that best distinguished the niches.

Examining the Environment Around Plaques

The integrated images also allowed the team to investigate proximity to amyloid deposits.

Researchers identified plaque locations through microscopy and assessed how cell populations and molecular signals varied with distance. Kruse reported enrichment of macrophages close to plaques, while T cells showed enrichment farther away.

The team could then examine gene-expression patterns near the deposits and investigate spatial relationships between transcripts and lipid signals.

These analyses generated candidates for follow-up rather than establishing what caused plaque formation. Their value lay in narrowing the investigation to molecular features associated with a defined pathological environment.

Continue reading below…
Application NotesLaboratory setup demonstrating HPLC-to-UHPLC method modernization
Modernizing routine HPLC methods does not automatically require full revalidation.
Discover how HPLC-to-UHPLC method modernization boosts lab efficiency and compliance with real-world examples and smart strategies.
Read More

Kruse also described applying the approach to Alzheimer’s brain tissue. Some molecular associations appeared across both disease settings, offering hypotheses for comparative research without implying that the underlying pathologies were equivalent.

Making Integration Analytically Meaningful

For laboratories developing spatial analysis workflows, the challenge extends beyond acquiring several image types. Accurate registration is essential to ensure that comparisons represent corresponding tissue locations, particularly when measurements come from adjacent sections.

Kruse’s presentation shows what that integration can enable: checking tissue identities, associating lipid profiles with cellular neighborhoods, and examining molecular changes around pathology. The analytical benefit comes from using each measurement to inform the interpretation of the others—and to define more focused questions for subsequent experiments.

This article was produced under Separation Science's AI Editorial Policy.

Add Separation Science as a preferred source on Google

Add Separation Science as a preferred Google source to see more of our trusted coverage

Meet the Author(s):

  • Aimee Cichocki is the Editorial Director at Separation Science and Chromatography Forum. Aimee brings a broad range of experience in creating, editing, and formatting scientific content. With a degree in medicinal chemistry, a 10-year background in formulation chemistry, an MBA, and a diverse background in publishing, Aimee guides editorial initiatives at Separation Science and Chromatography Forum. Aimee is dedicated to ensuring the delivery of informative, reliable, and practical content to our audience of analytical scientists.

    View Full Profile

Speaker

  • Separation Science Placeholder Image

    Angela Kruse, PhD., is an Assistant Professor in the Department of Microbial Infection and Immunity at The Ohio State University Wexner Medical Center.

    View Full Profile

Here are some related topics that may interest you:

Loading Next Article...
Loading Next Article...