Thermo_Fisher
Webinars

Enabling Deeper Phosphoproteomic Analysis Through Comprehensive Sample Preparation and Enrichment Strategies  

Available on Demand

Explore label-free acquisition strategies for effective phosphoproteome analysis with optimized workflows and instrumentation tips.

Overview

A deep and comprehensive understanding of the phosphoproteome is critical to gain insights into cellular regulation and disease mechanisms, such as those involved in cancer, autoimmune, and metabolic disorders. Mass spectrometry analysis enables a deep and comprehensive mechanism of inquiry into the phosphoproteome, but is often stymied by issues with high sample input requirements, low PTM stoichiometry over a high dynamic range of the total proteome, difficult sample preparation, highly labile modifications, poor ionization, and irreproducibility. Addressing these challenges involves optimizing sample preparation protocols, utilizing workflows that enrich for the phosphoproteome with high specificity, and applying application and acquisition strategies specific to your research goals and sample type.

By viewing this presentation, you will discover:

  • Strategies for successful sample preparation prior to phosphoenrichment
  • Phosphoenrichment workflow tips and tricks for highest identifications, phosphospecificity, reproducibility and confident localization
  • Upstream and downstream workflow options for phosphoenrichment experiments
  • Commercially available options for phosphoenrichment and their comparative performance on multiple mass spectrometry instrumentation platforms
  • Automation capabilities on Thermo Scientific™ KingFisher™ platforms
  • Acquisition strategies for label-free and TMT™- or Thermo Scientific™ TMT™ Pro-labeled phosphoproteome-enriched samples
  • Phosphoenrichment considerations in various biologically relevant sample types for highest confidently localized and reproducible identifications

Watch the presentation today to overcome your analytical bottlenecks and unlock deeper insights into the phosphoproteome.

What you need to know:

Format: On demand

Duration: 45 minutes 

Speakers

  • Leigh

    Leigh Foster

    R&D Scientist, Thermo Fisher ScientificThermo Fisher Scientific

    Leigh Foster has been an R&D Scientist at Thermo Fisher Scientific since 2014, specializing in mass spectrometry reagents and proteomics. She has driven the development of numerous solutions for quantitative multiplexing and PTM analysis, including the Thermo phospho-peptide enrichment kit. Her expertise spans magnetic-based multi-omic extraction, IP-MS workflows, and standard development for mass spectrometry and cryo-EM.

    View Full Profile
  • Sandra

    Sandra Spencer

    Director, Mass Spectrometry PlatformBC Cancer Research Institute

    Dr. Sandra Spencer leads the Mass Spectrometry platform at the BC Cancer Research Institute, translating complex analytical data into actionable oncology research. Following her graduate studies on ambient ionization at UNC Chapel Hill, she completed a postdoctoral fellowship at the University of Washington developing targeted clinical proteomics assays to help clinicians deepen their understanding of cancer biology.

    View Full Profile

Sponsored by

  • Thermo logo

Top Image Credit: