Eppendorf Launches Centrifuge 5811 R for Multipurpose Refrigerated Benchtop Workflows

The Centrifuge 5811 R Replaces A Long-Running Predecessor With R290 Propane Cooling And Broad Rotor Flexibility For Parallel Benchtop Workflows
Written bySharon Dong
Two researchers in white lab coats and blue gloves operating the Eppendorf Centrifuge 5811 R control panel in a well-lit modern laboratory — a refrigerated centrifuge for multipurpose benchtop workflows.

Eppendorf's Centrifuge 5811 R supports parallel workflows for tubes, plates, and bottles within a single refrigerated centrifuge footprint.

Credit: Eppendorf

Register for free to listen to this article
Listen with Speechify
0:00
2:00

In shared research labs, running tubes, microplates, and bottles through a single centrifuge without swapping rotors between protocols demands a level of flexibility that most benchtop instruments do not offer. Eppendorf now addresses that with the Centrifuge 5811 R, a refrigerated centrifuge that succeeds the Centrifuge 5810 R with R290 propane cooling, a 15-rotor portfolio, and a 3 L capacity.

Shared-Access Labs Require A Refrigerated Centrifuge That Handles Multiple Vessel Types

The Centrifuge 5811 R targets shared-access laboratories where one instrument must run tubes, microplates, and bottles across back-to-back protocols from different users. A single-application centrifuge cannot accommodate that range; cell pelleting, microplate assays, and large-bottle preparations each demand different rotor configurations, and swapping between them mid-schedule interrupts throughput. Many biologically sensitive samples also require cooling sustained throughout the spin itself, not just at startup, which adds temperature management to the configuration challenge.

"The refrigerated Centrifuge 5811 R is a benchtop system for labs where a single centrifuge needs to support many workflows in parallel," remarks Dr. Tim Schommartz, Global Marketing Manager of Eppendorf Group. "Tubes in the morning, plates in the afternoon, bottles for the next experiment – the Centrifuge 5811 R brings this capacity together in one reliable instrument."

Working in analytical science?

Register for a FREE Separation Science account to subscribe to the Separation Science Newsletter.

Subscribe for free

R290 Propane Cooling and its Role in Lab Sustainability

The Centrifuge 5811 R runs on R290 propane, a natural refrigerant with a global warming potential of 0.02 (IPCC Sixth Assessment Report, 100-year horizon) and an ozone depletion potential of 0. R290 sits well below the thresholds that EU Regulation 2024/573 on fluorinated greenhouse gases mandates on phased reduction of high-GWP synthetic refrigerants across European markets. The instrument also incorporates ECO shut-off, energy-efficient FastTemp, and an aerodynamic bucket design to cut power draw during routine operation.

Eppendorf uses recyclable aluminum for the rotor components, and the instrument ships in multiple bundle configurations to match different laboratory scales and rotor requirements.

What Applications Does The Centrifuge 5811 R Support?

The Centrifuge 5811 R supports diverse, back-to-back workflows in shared-access laboratories, seamlessly handling applications including:

  • Cell and Microorganism Harvesting (bacteria, yeast, algae, and mammalian cells)
  • Nucleic Acid and Protein Purification
  • Peripheral Blood Mononuclear Cell (PBMC) Isolation: When isolating by density gradient centrifugation, precise braking ramp control preserves the density interface.

Max Speed20,913 × g / 14,000 rpm
Max Capacity3 L (4 × 750 mL, 28 × 50 mL, 56 × 15 mL)
Temperature Range-9 °C to +40 °C
RefrigerantR290 propane (GWP 0.02 per IPCC AR6, ODP 0)
User Programs35
Rotor Portfolio15 rotors, broad adapter selection
5810 R Rotor Compatibility
16 of 17 existing rotors
Noise Level<56 dB(A) with Rotor S-4-104

A Versatile, Eco-Conscious Centrifuge for Shared Labs

The Centrifuge 5811 R gives shared-access laboratories a single refrigerated benchtop instrument capable of running tubes, microplates, and bottles across parallel protocols, without the rotor compromises that have historically made that combination difficult. Its adoption of R290 propane refrigerant, with a GWP of 0.02, positions it directly in line with the F-gas reduction requirements taking hold across European markets, making the upgrade decision relevant beyond performance alone.

This article is based on a press release issued by Eppendorf and was produced under Separation Science's Editorial Guidelines.

Add Separation Science as a preferred source on Google

Add Separation Science as a preferred Google source to see more of our trusted coverage

Meet the Author(s):

  • black and white photo of Sharon Dong in a button up blouse, smiling
    Sharon Dong, BSc (Hons), MSc joined LabX Media Group (LMG) in 2026 as a Product News & Intelligence Editor. She has a strong background in cellular biology, microbiology, immunology, and molecular genetics. She is an experienced science education and outreach facilitator. Sharon is passionate about communicating science in ways that are clear, engaging, and accessible to a broad audience. In her free time, she enjoys solving jigsaw puzzles and cooking. Sharon can be reached at sdong@labx.com.
    View Full Profile

Here are some related topics that may interest you:

Loading Next Article...
Loading Next Article...