HPR-20 R&D: Hiden Analytical's Bench-Top System for Evolved Gas Analysis

Configurable mass range and sub-5-ppb detection make the HPR-20 R&D a practical tool for multi-species gas monitoring across energy and catalysis research
Written bySharon Dong
Bench-top quadrupole mass spectrometer connected via insulated capillary to a tubular reactor assembly, with a real-time mass spectrum displayed on a monitor.

A bench-top mass spectrometer and scroll pump setup illustrates the compact footprint and direct reactor coupling central to real-time evolved gas analysis.

Google Flow (2026)

Register for free to listen to this article
Listen with Speechify
0:00
3:00

Hiden Analytical's flagship HPR-20 R&D is a bench-top quadrupole mass spectrometer built for real-time evolved gas analysis, with detection sensitivity to 5 ppb and mass range options up to 1000 amu. It targets continuous, multi-species gas and vapor monitoring across carbon capture, green hydrogen, catalysis, and thermal analysis/mass spectrometry (TA/MS) workflows. Fast response and a configurable sampling interface let researchers match the system to their experimental setup without compromising measurement quality.

Hiden Analytical HPR-20 R&D bench-top quadrupole mass spectrometer with QIC capillary assembly and vacuum control unit on a white background.

The HPR-20 R&D houses a triple filter mass spectrometer, vacuum control unit, and heated QIC capillary assembly in a single bench-top chassis.

Hiden Analytical (2026)

David Lundie, Technical Director, Hiden Analytical, notes: "Carbon capture research depends on more than measuring CO2 alone. Researchers need to understand how gases behave across adsorption, reaction, regeneration and process cycling. The HPR-20 R&D gives advanced R&D teams the sensitivity, fast response and flexible sampling needed to monitor complex gas and vapour environments in real time."

Evolved Gas Analysis: The Measurement Challenge in Carbon Capture Research

Tracking CO₂ and related process gases across adsorption cycles, sorbent regeneration, breakthrough events, and trace by-product formation is a central analytical challenge in carbon capture research, where each stage of the capture cycle can produce a distinct gas-phase signature. Understanding how those signatures shift under varying reactor conditions requires continuous, selective monitoring of multiple species at once. Evolved gas analysis with real-time mass spectrometry meets this demand by providing the temporal resolution and sensitivity that batch or offline methods cannot.

Working in analytical science?

Register for a FREE Separation Science account to subscribe to the Separation Science Newsletter.

Subscribe for free

Standards such as the ISO 10396:2007 emissions sampling guidance illustrate the data quality rigor placed on gas measurement at the industrial scale, covering representative sampling for automated determination of gas concentrations from stationary sources. Research and pilot teams face similar expectations, compounded by additional variables: flow rate instability, mixed gas matrices, and custom reactor geometries. Meeting those demands requires analytical platforms that combine low detection limits with broad configuration flexibility.

HPR-20 R&D Instrument Specifications

A triple filter mass spectrometer anchors the HPR-20 R&D, delivering improved resolution and enhanced abundance sensitivity across five configurable operating parameters:

  • Detection Limit: To 5 ppb, subject to spectral interference; suited to trace gas and vapour monitoring
  • Mass Range Options: 200, 300, 500, or 1000 amu, selectable to match the analyte scope of each application
  • Heated QIC Interface: The Quartz Inert Capillary (QIC) provides continuous gas and vapour sampling via a heated, inert-lined inlet
  • Sample Flow Rate: Adjustable from less than 1 ml/min to more than 20 ml/min by inlet selection
  • APSI-MS Mode: Atmospheric Pressure Soft Ionization reduces fragmentation for cleaner identification of selected species

Which Research Applications Does the HPR-20 R&D Support?

The HPR-20 R&D covers six primary research domains, each requiring selective, real-time gas monitoring of distinct species classes. For carbon capture specifically, the system handles CO₂ adsorption and desorption testing, sorbent regeneration monitoring, breakthrough curve analysis, chemical looping research, and simulated flue gas experiments. Published studies in the press release document its use in biogas pyrolysis (tracking methane conversion, hydrogen yield, and carbon capture potential) and in biopolymer hydrolysis kinetics, where it helped build kinetic models for depolymerization.


Scatter plot comparing CH₄ conversion and solid carbon yield across fixed bed and empty tube reactor configurations in biogas pyrolysis research.

Fixed bed reactors reached 95–100% CH₄ conversion with solid carbon yields above 90%, versus 47–57% in empty tube configurations.

Hiden Analytical (2026)

Its application range spans energy, environmental, and materials research, as mapped below by analytical role:

Application AreaAnalytical Role
Carbon CaptureCO₂ adsorption/desorption, sorbent regeneration, breakthrough monitoring
Green HydrogenProduct gas purity and yield monitoring during reforming and pyrolysis
Catalysis and Thermal Analysis (TA/MS)Evolved gas identification during temperature-programmed experiments
Electrochemistry and Fuel CellsGas product detection and correlation with electrochemical parameters
Environmental MonitoringReal-time tracking of trace emissions and atmospheric gas species
CVD / MOCVD / ALCVDProcess gas monitoring in thin film deposition environments

Software, Connectivity, and Extended Applications

Beyond the six primary domains, the QIC sampling interface supports glovebox monitoring, gas separation studies, mud logging, and near-atmospheric XPS/APXPS through its compatibility with a broad range of custom and standard research connections. MASsoft Professional Edition software controls the instrument via USB 2.0, RS232, or Ethernet, and overlays mass spectrometer data with inputs from coupled thermal analysis equipment for integrated TA/MS workflows. Together, these software and hardware options give research groups a single platform adaptable from benchtop experiments to more complex, multi-instrument configurations.

Bench-Top Evolved Gas Analysis Across Energy and Catalysis Research

Real-time evolved gas analysis sits at the centre of some of the most active research fields in energy and materials science, and the HPR-20 R&D is designed to meet that demand across a broad and varied application landscape. Its value lies not in any single specification but in the combination of trace-level sensitivity, configurable sampling, and multi-species monitoring in a format that fits standard laboratory infrastructure. For research groups working at the intersection of gas-phase measurement and emerging energy technologies, it represents a practical and adaptable analytical option.

This article is based on a press release issued by Hiden Analytical and was produced under Separation Science's AI Editorial Policy.

Add Separation Science as a preferred source on Google

Add Separation Science as a preferred Google source to see more of our trusted coverage

Meet the Author(s):

  • black and white photo of Sharon Dong in a button up blouse, smiling
    Sharon Dong, BSc (Hons), MSc joined LabX Media Group (LMG) in 2026 as a Product News & Intelligence Editor. She has a strong background in cellular biology, microbiology, immunology, and molecular genetics. She is an experienced science education and outreach facilitator. Sharon is passionate about communicating science in ways that are clear, engaging, and accessible to a broad audience. In her free time, she enjoys solving jigsaw puzzles and cooking. Sharon can be reached at sdong@labx.com.
    View Full Profile

Here are some related topics that may interest you:

Loading Next Article...
Loading Next Article...