Karl Fischer Titration Week

Available on Demand

This titration event covers different aspects that need to be considered when determining the water content in products, raw materials, and other substances. Experts from the life science business of Merck KGaA, Darmstadt, Germany, Metrohm AG, and Mettler Toledo present and discuss different steps of the Karl Fischer titration process and how to improve it.

Brought to you byMettler-Toledo, Separation Science, and Merck KGaA, Darmstadt, Germany
Three Webinars and a Roundtable with Experts from MilliporeSigma, Metrohm & Mettler Toledo (Plus a Bonus FAQ PDF)

A Week Dedicated to Karl Fischer Titration!

Karl Fischer titration is still the most used, most accurate, and fastest method to determine water content in all kinds of sample matrices. This titration week covers different aspects that need to be considered when determining the water content in products, raw materials, and other substances. Experts from the life science business of Merck KGaA, Darmstadt, Germany, Metrohm AG, and Mettler Toledo will present and discuss different steps of the Karl Fischer titration process and how to improve it. Learnings include:

• Karl Fischer titration process and tips for how to improve it
• Karl Fischer oven method and its advantages
• Reference materials to use for titer determination, instrument check, and result verification
• Parameters needed to validate a Karl Fischer titration application
 • News and future aspects of Karl Fischer titration

You must register separately for each day you wish to attend using the forms below.

The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada.
For further information about our names in the US, Canada and internationally, please refer to our disclaimer at emdgroup.com.

FormHeader_Part1

How to Achieve Accurate Water Content Results with Karl Fischer Titration
Bettina Straub-Jubb, Product Manager & Lead Expert for Titration at the life science business of Merck KGaA, Darmstadt, Germany
Transparent and accurate analysis results are an important prerequisite for meeting your customers' quality expectations on products, raw materials and processes. A central analytical parameter is the water content. Water can influence stability, durability, permeability, or consistency of materials, or the energy consumption, yield, and safety in production processes. Therefore, exact water determination is necessary in a wide variety of industries. The Karl Fischer titration method is still the most used, fastest, and most precise method for measuring water content to get accurate, transparent, and comparable results. By watching this presentation, you will learn:

  • The difference between Volumetry and Coulometry
  • How to improve your Karl Fischer titration process
  • The key quality assurance requirement
  • How to perform an accurate titer determination
  • Tips to avoid failures

Duration: Approximately 60 mins

Register for Part 1

First name*Last Name*Email*

FormHeader_Part2

The Karl Fischer Oven Method – Step by Step
Michael Margreth, Application Specialist - Karl Fischer Titration and Water Determination, Metrohm
Karl Fischer (KF) titration is a standard method for the water content determination in all types of substances. However, for various reasons, some substances are not suitable for a direct Karl Fischer titration. These reasons include that they undergo side reaction with KF reagents; they contaminate the titration cell and/or the electrodes; the substances are poorly soluble in alcohol; they release their water only slowly; or the water is released at high temperatures only. These problems can be avoided by using the oven method. This makes the KF oven method the perfect solution for the analysis of difficult samples. By watching this presentation, you will learn:

  • The principle of the oven method
  • How to properly prepare your titration system with an oven
  • How to prepare your sample
  • How to select the optimal oven temperature

After viewing this webinar, you will know how to perform accurate sample measurements using the oven method.

Importance of CRM-grade Karl Fischer Standards for Accurate KF Titration
Shailly Krishna-Rajusth, Product Manager for Physical & Chemical Property Standards at the life science business of Merck KGaA, Darmstadt, Germany
Karl Fischer (KF) titration is one of the most rapid and accurate methods to determine water content in various samples. For accurate KF titration, high quality Certified Reference Materials (CRMs) are essential. In this webinar, we will present key reference material terms, different quality grades of reference materials, and an overview of our portfolio of high-quality CRM-grade KF Standards. By watching this presentation, you will learn:

  • Key terms: Metrological Traceability, Quality Grades, 17025 & 17034 Accreditation
  • The importance of using the right quality grade of KF standards for your application
  • An overview of our unmatched portfolio of KF standards 

Duration: Approximately 60 mins

Register for Part 2

First name*Last Name*Email*

FormHeader_Part3

Direct Karl-Fischer Titration or Gas Phase Extraction – A Closer Look
Thomas Hitz, PhD Application Development, Automated Karl-Fischer Titration, Mettler Toledo
In this presentation we will compare the direct addition with the gas phase extraction method. For this purpose, various sample types were analyzed by either direct addition, gas phase extraction, or both. Among the tested sample types are powders, oils, and cannabis flower. We will discuss the challenges that such samples represent and highlight the analytical measures that will ensure to obtain the best results possible. By watching this presentation, you will learn about:

  • Direct titration vs. gas phase extraction method
  • Advantages of the Karl Fischer oven method (gas phase extraction)
  • Application examples: oils / cannabis flower

Validation of Parameters for Karl Fischer Titration
Angela Schwehn, Laboratory Scientist in the R&D Department of the life science business of Merck KGaA, Darmstadt, Germany
Validation of parameters for a Karl Fischer titration method is an essential prerequisite for laboratories. Performance characteristics of the procedure need to meet the requirements for its intended purpose. You will learn typical analytical performance parameters that should be considered in the validation of the Karl Fischer titration procedures. The objective of this session is to present the requirements for a titration process. By watching this presentation, you will learn about:

  • General aspects of validation
  • Required validation parameters
  • How to verify the suitability and accuracy of a titration method
  • An overview of the parameters described in ICH (International Council for Harmonization) guidance Q2(R1) and USP general chapter <1225> (selectivity, linearity, accuracy & reproducibility)

Duration: Approximately 45 mins

Register for Part 3

First name*Last Name*Email*

FormHeader_22June

Live Roundtable Expert Discussion
Together with our partners Metrohm and Mettler Toledo, MilliporeSigma will discuss the trends and key aspects of Karl Fischer titration. We will come back on some questions asked during the earlier three webinars, as well as answering new questions during the roundtable discussion.  
This live event will be moderated by Separation Science and participants will include Bettina Straub-Jubb, Dr. Shailly Krishna Rajusth, and Angela Schwehn from the life science business of Merck KGaA, Darmstadt, Germany, Dr. Leila Mosberger from Mettler-Toledo, and Michael Margreth from Metrohm AG. 

BettinaStraubJubb
ShaillyKrishnaRajusth
AngelaSchwehn
LeilaMosberger
MichaelMargreth

Start Time:
9am BST / 10am CEST / 1.30pm IST / 4pm SGT / 6pm AEST

Register for Part 4

First name*Last Name*Email*

Bonus Content: Access the FAQS 

A PDF copy of the frequently asked questions that emerged during the 'Karl Fischer Titration Week' is also available to download. This download will be included with all on-demand registrations.

Sponsors

TitrationWeek_Sponsors_v2

The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada.

For further information about our names in the US, Canada and internationally, please refer to our disclaimer at emdgroup.com.

Registrants to the Karl Fischer Titration series of presentations are covered by the Eclipse Business Media Privacy Policy. Information you provide will be shared with the sponsors for this content. Eclipse Business Media Ltd may contact you to offer you content based on your specific interests. You may opt-out at any time