Novel Analytical Tools for Per- and Poly-fluoroalkyl Compounds and ISO21675

Development of ISO21675, the most recent International Standard Method for PFAS in water is described. Then, novel analytical tools for volatile/neutral PFAS in air and water are discussed.
Updated
AgilentWeb_040522_WebHeader_OND

NobuyoshiYamashita_80_v2Separation Science, in collaboration with Agilent, offers an on-demand symposium covering new methods in PFAS testing, featuring thought leaders from across the globe. One key talk available to watch is 'Novel Analytical Tools for Per- and Poly-fluoroalkyl Compounds and ISO21675' given by Dr Nobuyoshi Yamashita (Chief Senior Research Scientist at the Research Institute for Environmental Management, National Institute of Advanced Industrial Science and Technology [AIST], Japan). Below is an outline of the presentation:

Format: On-demand Presentation

Overview:
Development of ISO21675, the most recent International Standard Method for PFAS in water is described. Then, novel analytical tools for volatile/neutral PFAS in air and water are discussed. A brand-new technology, simultaneous analysis of neutral and ionizable per- and polyfluoroalkyl substances in air is firstly reported in front of audience. This research tool enables the next generation of mass balance analysis of all PFAS in the environment, namely more than five thousand chemicals. Heart of lecture is “how important QAQC for PFAS analysis”. Sensitivity of "1 pg/L" with 10%RSD and "1 ng/L" with 50%RSD are completely different world. Which do you choose?

By watching this presentation you will learn about:

  • The history and advantage of ISO21675
  • Simultaneous analysis of neutral and ionizable per- and polyfluoroalkyl substances in air
  • Quality assurance and quality control of solid phase extraction for PFAS in water and novel analytical techniques for PFAS analysis

Register to watch the presentation by clicking on the button below:

In addition, you'll gain access to a series of presentations unique to this on-demand symposium:

AddPres_ChenLatest Regulations & Standards on PFAS Testing in the Materials Industry
Dr Yuhong Chen (Global Materials Segment, Applied Markets, Agilent Technologies)

AddPres_GilSampling and Analysis of Volatile PFAS in Air by TD-GC-MS
Carlos Gil (Business Development Manager, Markes International GmbH)

AddPres_BaumannStreamlined PFAS Annotation and Visualization with FluoroMatch Flow and Visualizer
Stephen Baumann (Application Applied Segment Manager, Agilent Technologies)

AddPres_ThaxtonUsing Thermal Desorption and GC-MS/MS for the Analysis of PFAS Compounds in Air for Improved Detectability & Reliability
Kurt Thaxton (Gerstel)