Webinars

Perform like a PRO: Robust ICP-OES analysis with the new iCAP PRO Series ICP-OES

Available on Demand

A technique of choice for elemental analysis is inductively coupled plasma-optical emission spectroscopy (ICP-OES), which is ideally suited for a range of sample types. However, some samples present analytical challenges including high matrix samples and samples which produce complex spectrum impacting accuracy. Watch this presentation to find out how the latest ICP-OES technology can address these issues and improve your elemental analysis.

Written byDr Sukanya Sengupta and Nora Bartsch (Thermo Fisher Scientific)

Register for this on-demand learning presentation...

A technique of choice for elemental analysis is inductively coupled plasma-optical emission spectroscopy (ICP-OES), which is ideally suited for a range of sample types. However, some samples present analytical challenges - these include:

  • High matrix samples such as brines, which impact the sample introduction
  • Samples which produce complex spectrum impacting accuracy.

Watch this presentation to find out how the latest ICP-OES technology can address these issues and improve your elemental analysis.

By viewing this presentation you will:

  • Learn how to approach the analysis of high matrix samples on both radial and duo ICP-OES systems without impacting performance.
  • Learn how the latest advancements in optics and detector technology can aid in interference-free analysis.
  • Discover ways to improve speed of analysis for your applications.

To register for this on-demand webinar please complete the form on the right. By clicking the 'View the on-demand presentation' button, you submit your information to the webinar organizer, who as an independent content provider to analytical and laboratory scientists, will use it to communicate with you regarding this event and other similar platforms run in collaboration with other parties.

Separation Science, in collaboration with Thermo Fisher Scientific, offers an on-demand webinar looking at how the latest ICP-OES technology can improve your elemental analysis.

Duration: Approximately 60 minutes

Presenters:
Dr Sukanya Sengupta (Thermo Fisher Scientific)
Sukanya joined Thermo Fisher Scientific in Bremen in 2020 as Application Specialist for ICP-OES, where she assists customers in their daily laboratory routines by developing new methods and applications that meet the industry/research requirements.

Nora Bartsch (Thermo Fisher Scientific)
Nora is an Application Specialist for
ICP-OES, where she supports the customer with the development and implementation of new methods and regulations in their laboratory routines.

Sponsor: