Plasma Proteomics: Distinguishing Biological Signals From Sample Preparation Artifacts

Distinguishing preparation artifacts from disease-related signals requires a closer look at what plasma workflows retain—and what they remove.
Written byAimee Cichocki
Presented bySasha A. Singh, MSc, PhD, FAHA and Phillip Owens
Vial containing plasma for proteomics sample preparation

Google Flow 2026

Register for free to listen to this article
Listen with Speechify
0:00
2:00

Platelet-derived proteins in a plasma sample can raise concerns about collection and handling. But they can also reflect events occurring in the patient before blood collection. Distinguishing those sources is important when researchers decide which signals to investigate and which to exclude.

During a US HUPO webinar, Dr. Sasha A. Singh and Dr. Phillip Owens examined that distinction from complementary perspectives. Their presentations challenged assumptions about what belongs in plasma and explored how cell-derived material can contribute to biomarker discovery.

For analytical laboratories, the question extends beyond obtaining a consistent preparation. Does that preparation retain the biological information the study needs?

Reconsidering What Plasma Contains

Singh describes how advances in plasma proteomics prompted her to reassess expectations about sample composition. High-abundance proteins have long constrained MS analysis, masking signals from lower-abundance components. Enrichment technologies now allow researchers to examine more of that complexity.

As proteomics workflows expand protein identification and quantification, researchers face questions about the origin and significance of the additional signals they detect.

Working in analytical science?

Register for a FREE Separation Science account to subscribe to the Separation Science Newsletter.

Subscribe for free

Singh argues that plasma can contain biologically meaningful material beyond conventionally secreted proteins. Extracellular vesicles, platelet-derived components, and material released from stressed tissues may all contribute information about disease processes.

She illustrates the point with cardiovascular research. Activated platelets associated with diseased tissue can release their contents into circulation. Their signatures in plasma may therefore reflect activity at a lesion, rather than activation introduced during sample preparation.

The presence of a cellular protein alone cannot establish its origin. It creates a question that requires biological context and evidence about sample handling.

Following a Platelet-Derived Signal

Owens develops this argument through research on abdominal aortic aneurysm. His presentation focuses on how platelet activity at the disease site can generate circulating signals with potential biomarker value.

One example is soluble glycoprotein VI, or sGPVI, which forms when a platelet surface receptor undergoes cleavage. Owens describes how investigating this signal connected local platelet activity with measurements in plasma.

The published study examines two independent patient cohorts and finds that sGPVI associated with aneurysm growth rate.

The example demonstrates why researchers should investigate a signal’s origin before dismissing it as contamination. Platelet-associated material can reflect disease biology, even though platelets also represent a source of preanalytical variation.

Owens also highlights extracellular vesicles as carriers of circulating biological information. Removing them changes the fraction under investigation and can exclude signals relevant to the study.

Separating Biology From Handling Effects

Neither presentation removes the need for rigorous sample preparation. Owens emphasizes that collection and processing can activate platelets and alter measured protein levels. Anticoagulant choice, temperature, centrifugation, and collection materials all require attention.

The challenge is to distinguish release occurring in the patient from release introduced after collection. A platelet-derived signal could arise from either source, making consistent handling essential to interpretation.

Preparation choices also affect what downstream analysis can recover. Research coauthored by Singh on plasma proteome recovery found that differences among sample sources and processing practices influenced results obtained with a particle-based enrichment workflow.

For biomarker studies, cleanup therefore involves a biological decision as well as an analytical one. Researchers need to define the fraction they intend to measure, control handling-induced changes, and assess unexpected findings against the disease context. A cleaner preparation may improve one measurement while excluding information needed for another.

This article was produced under Separation Science's AI Editorial Policy.

Add Separation Science as a preferred source on Google

Add Separation Science as a preferred Google source to see more of our trusted coverage

Meet the Author(s):

  • Aimee Cichocki is the Editorial Director at Separation Science and Chromatography Forum. Aimee brings a broad range of experience in creating, editing, and formatting scientific content. With a degree in medicinal chemistry, a 10-year background in formulation chemistry, an MBA, and a diverse background in publishing, Aimee guides editorial initiatives at Separation Science and Chromatography Forum. Aimee is dedicated to ensuring the delivery of informative, reliable, and practical content to our audience of analytical scientists.

    View Full Profile

Speakers

Here are some related topics that may interest you:

Loading Next Article...
Loading Next Article...