Restek Introduces PFAS-10 CRM Mix for Japan Water Supply Act Compliance

One Ampul, Ten PFAS Compounds: Restek's PFAS-10 CRM Addresses Japan's New Mandatory Drinking Water Standards
Written bySharon Dong
A clear glass ampul and a rack of 2mL autosampler vials, containing a PFAS water testing standard, sit on a stainless steel laboratory benchtop with an LC-MS system softly blurred in the background.

Restek's PFAS-10 CRM consolidates ten linear PFAS compounds into a single ampul for routine LC-MS/MS calibration.

Gemini (2026)

Register for free to listen to this article
Listen with Speechify
0:00
2:00

Japan's amended Water Supply Act imposes enforceable drinking water limits on per- and polyfluoroalkyl substances (PFAS) from April 2026, creating an immediate need for PFAS water testing standards aligned with the revised requirements. Restek has launched the PFAS-10 certified reference material (CRM) Mix, a single ready-to-use ampul containing ten linear PFAS compounds covering all analytes the Act requires and recommends.

How Has Japan's Water Supply Act Changed PFAS Testing Requirements?

The April 1, 2026 revision converts quarterly PFAS water testing from a voluntary practice to a mandatory obligation: water utilities must act when the combined concentration of perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) in tap water exceeds 50 ng/L. Japan's standard notification method classifies perfluorohexanesulfonic acid (PFHxS) as a recommended monitoring compound alongside PFOS and PFOA.

Sourcing individual component standards and blending calibration solutions from separate lots raises error risk and extends turnaround time; a single-ampul CRM that covers all targeted analytes directly reduces both. Restek formulated PFAS-10 in its ISO-accredited labs from materials greater than 99% pure. ¹⁹F NMR identifies isomers, LC-MS/MS quantifies trace PFAS impurities below 1%, and expanded data packs document that no off-target analytes affect quantitative results.

Working in analytical science?

Register for a FREE Separation Science account to subscribe to the Separation Science Newsletter.

Subscribe for free

PFAS-10 covers the analyte scope, purity standard, and documentation needs for compliant PFAS water testing programs:

  • Ten Linear Compounds required and recommended under the Japan Water Supply Act (April 2026)
  • Greater Than 99% Purity with isomers identified by ¹⁹F NMR; trace impurities quantified by LC-MS/MS below 1%
  • Expanded Data Packs with lot-specific impurity profiles for every batch
  • Verified Composition And Stability supporting long shelf life and consistent method development
  • In Stock And Ready To Ship from Restek's certified reference material portfolio

PFAS-10 Applications: Drinking Water, Compliance, and Beyond

Beyond Japan Water Supply Act compliance, PFAS-10 suits any PFAS water testing program built around linear compound targets. The table below maps its ten-compound scope to key analytical workflows and geographic frameworks.

Application AreaRelevance of PFAS-10
Amended Water Supply Act Compliance (Japan)
Covers PFOS and PFOA (mandatory standards) and PFHxS (recommended study item), plus seven further linear compounds
Drinking Water and Wastewater Monitoring
Supports routine LC-MS/MS quantification for regulatory compliance programs
PFAS Method Development
Enables multi-analyte calibration from a single preparation step
Asia-Pacific Environmental ProgramsApplicable to regional monitoring frameworks sharing linear PFAS target lists with Japan's revised standards

PFAS-10 joins a growing Restek portfolio that includes single-component standards and method-specific mixes for EPA Methods 533 and 537.1, providing PFAS water testing coverage across a range of global regulatory frameworks.

Restek's PFAS-10 Reduces Calibration Complexity for Compliant PFAS Water Testing

PFAS-10 consolidates ten linear compounds into one traceable reference material, eliminating the need to source, blend, and manage multiple individual standards for Japan Water Supply Act compliance. Every batch ships from stock with purity above 99% and lot-specific impurity data included, ready to integrate into existing LC-MS/MS workflows. For labs meeting Japan's mandatory quarterly testing obligations, PFAS-10 offers a direct, documented path to compliant PFAS water testing.

This article is based on a press release issued by Restek Corporation and was produced under Separation Science's AI Editorial Guidelines.

Add Separation Science as a preferred source on Google

Add Separation Science as a preferred Google source to see more of our trusted coverage

Meet the Author(s):

  • black and white photo of Sharon Dong in a button up blouse, smiling
    Sharon Dong, BSc (Hons), MSc joined LabX Media Group (LMG) in 2026 as a Product News & Intelligence Editor. She has a strong background in cellular biology, microbiology, immunology, and molecular genetics. She is an experienced science education and outreach facilitator. Sharon is passionate about communicating science in ways that are clear, engaging, and accessible to a broad audience. In her free time, she enjoys solving jigsaw puzzles and cooking. Sharon can be reached at sdong@labx.com.
    View Full Profile

Here are some related topics that may interest you:

Loading Next Article...
Loading Next Article...