Dr. Gesa Schad, HPLC Product Manager at Shimadzu Europa GmbH, is well acquainted with the evolving demands of analytical chemistry. Specializing in method development, workflow automation, and sustainable separation solutions, she actively guides the industry's technical direction, most recently serving on the Industry Advisory Board for the International Symposium on Chromatography (ISC 2026). At the symposium, she shared her insights as a key panelist for sessions on education. Drawing from her experience, she highlights several major shifts occurring in separation science.
Navigating the Shift Toward Automation
Routine testing labs face significant operational friction as the demographics of instrument operators change. "Instrument operators are increasingly just general users rather than analytical chemists," explains Dr. Schad. "We rarely see dedicated experts setting up and running methods anymore."
Because of this skills shift, modern operators lack deep troubleshooting expertise, driving a need for robust and reliable systems. "Laboratories want everything automated to increase speed and reduce errors," notes Schad. "When operators lack troubleshooting expertise, labs must rely heavily on their instruments to perform flawlessly day in and day out," she adds.
Balancing Speed, Integrity, and Sustainability
As laboratories continuously push for higher sample throughput and shorter run times, traditional methods introduce equipment strain. "Adopting UHPLC introduces higher pressures, which inevitably increases wear and tear on the instruments," Schad asserts. To increase analytical speed without sacrificing stability, she advocates for miniaturization. "We are currently advocating for 1 mm columns and lower flow rates," she explains, though she specifies that labs require instruments with very small inner volumes to ensure the chromatography isn't compromised.
"SFC is an alternative I highly recommend, as it allows for faster separations at lower pressures," Schad adds.
Green separation science and solvent reduction were major focal points at ISC 2026. However, regulated pharmaceutical QC labs face substantial hurdles in adopting alternative mobile phases. "HPLC is deeply established in QC labs, and it cannot be replaced overnight," Schad observes. "Labs cannot easily change these processes because everything is strictly validated under GMP."
Still, the industry is making strides in evaluating alternatives such as bioethanol. Schad highlights a recent collaboration with a university in Greece that created a database tracking the true CO2 footprint of solvents. "They examined solvent "greenness" throughout their complete life cycle—not just pure toxicology, but production methods and disposal options," she explains. When factoring in these comprehensive elements, she notes that SFC solvents naturally ranked highest because they are non-toxic, though water also qualifies as a fundamentally green solvent.
Ensuring Method Robustness with AQbD
Method transfer between R&D teams and routine testing environments often introduces unexpected operational variability. To build inherently robust methods that withstand day-to-day shifts, Schad urges scientists to adopt an analytical quality by design (AQbD) approach.
"Success relies on building quality into your method from the very beginning," emphasizes Schad. "We always recommend an analytical quality by design approach, incorporating design of experiments directly into method development."
She advises using statistical software to identify which specific parameters affect the separation most. From there, scientists must map out allowable variations. "By creating a design space, you can test variations around your optimal method to see how robust it is against minor shifts," Schad notes. Ultimately, early testing is critical so that slight flow or volume variations on new instruments do not push final results out of specification. "You must fully understand your method and validate it for robustness right from the start," she advises.
The Pragmatic View on AI in Separation Science
While computational modeling and automated method development generated notable interest at this year's show, highly regulated environments are expected to adopt these tools slowly. "Regulated pharma labs are historically very slow to adopt new technologies," observes Schad. "Even though UHPLC has been available for 20 years, standard HPLC remains the go-to method in quality control labs."
When it comes to artificial intelligence, Schad draws a firm line on current capabilities. "AI can already be utilized effectively for initial method development," she states, noting that the final method will be tangibly tested in the lab regardless. "However, when it comes to downstream tasks including data evaluation, the technology simply isn't there yet." Human scientists must still critically evaluate AI-generated results to ensure the technology does not hallucinate data. "The real danger of AI is its tendency to confidently cover up its own knowledge gaps," Schad cautions.
Looking ahead over the next five years, the most transformative impact on liquid chromatography will not come from an overnight AI revolution, but from practical, mechanical upgrades. "The drive toward automation is the most significant trend, and we are already seeing labs implement it with great success," concludes Schad.
Responses have been edited for length and clarity.