What Makes a Useful Blood-Based Protein Biomarker?

Biological variation and uncertainty about tissue origin complicate the path from circulating protein measurements to biomarkers that can inform clinical research.
Written byAimee Cichocki
Presented byNathan Basisty, PhD.
Plasma proteomics in laboratory setting with proteins visualized

Google Flow 2026

Register for free to listen to this article
Listen with Speechify
0:00
3:00

Measuring more proteins in blood expands the possibilities for biomarker discovery. Determining what those measurements reveal about a disease, tissue, or treatment response remains a separate challenge.

During a US HUPO webinar, Nathan Basisty of the National Institute on Aging examined that gap. His presentation explored how researchers can connect circulating protein signatures with biological outcomes while accounting for variation that can strengthen, obscure, or confound an association.

For analytical scientists, the implications reach from study design to interpretation: greater proteomic depth creates opportunities, but useful biomarkers require a clear purpose and appropriate comparisons.

Defining What the Biomarker Must Reveal

Basisty began with the intended use of a measurement. A biomarker might help identify patients for treatment, assess whether an intervention produces its intended effect, or investigate relationships between a biological process and subsequent disease. He directed researchers to the FNIH Biomarkers Consortium for resources on biomarker development and applications.

He illustrated these possibilities through cellular senescence. A circulating protein signature associated with senescent-cell burden could potentially support patient stratification or help researchers evaluate treatments designed to remove those cells.

Working in analytical science?

Register for a FREE Separation Science account to subscribe to the Separation Science Newsletter.

Subscribe for free

These applications place different demands on the evidence. An association with disease status does not establish that a signature can monitor treatment response. Defining the intended use helps researchers determine which samples, comparisons, and outcomes a study needs.

This distinction is important in aging research, where investigators seek measurements that respond within the duration of a clinical trial, while the outcomes of interest may develop over many years.

Connecting Blood Measurements With Tissue Biology

Blood provides access to signals from across the body, but that breadth complicates interpretation. A change in a circulating protein does not necessarily identify the tissue responsible.

Basisty described efforts to develop tissue-associated protein panels using reference datasets. The approach selects proteins enriched in particular tissues or cell types, then investigates whether their circulating signatures provide information about related outcomes. Research on organ aging signatures illustrates how tissue-enriched plasma protein panels can support models of organ aging and disease risk.

His team applied a related strategy using data-independent acquisition proteomics to characterize senescent cells from different tissue origins. They then assessed whether cell-type-associated signatures added value beyond a general senescence signature.

In the analysis he presented, signatures derived from lung cells showed stronger associations with chronic obstructive pulmonary disease status than the general signature.

The finding suggested that tissue-informed panels could improve biological interpretation. Basisty also emphasized that the approach remains an area for investigation, including establishing which tissues researchers can assess and how confidently circulating measurements reflect their condition.

Accounting for Biological Variation

Even when an assay performs consistently, biological differences can complicate comparisons.

Basisty highlighted collection time as one consideration. Daily oscillations in circulating proteins can create apparent differences between groups or mask an association when sampling times do not align.

Genetic background provided another example. In an aging study involving two mouse strains, his team found substantial strain-associated differences in the circulating proteome. For one protein he discussed, those differences exceeded the age-related change.

Continue reading below…
eBooksPhosphoproteome analysis with optimized sample preparation strategies.
Mastering Quality Control for Next-Generation Peptide Therapeutics
Discover robust LC/MS and spectroscopy workflows designed to overcome quality control challenges in GLP-1 receptor agonists and therapeutic peptides
Read More

Such variation can confound an analysis, but it can also reveal biology. Basisty described how strain-associated protein patterns aligned with other evidence of differences in inflammation and aging phenotypes.

The analytical task is to distinguish variation relevant to the research question from variation that compromises the comparison.

Designing Studies Around Interpretation

Advances in proteomics workflows support broader protein identification and quantification across biological samples. Basisty’s presentation underscored the study-design work needed to turn that capability into interpretable biomarker evidence.

Researchers need to define what a signature should reveal, assess the basis for assigning tissue relevance, and account for biological variables that influence circulating abundance. Those decisions help determine whether a protein association can support the next stage of investigation—and what further validation it requires.

This article was produced under Separation Science's AI Editorial Policy.

Add Separation Science as a preferred source on Google

Add Separation Science as a preferred Google source to see more of our trusted coverage

Meet the Author(s):

  • Aimee Cichocki is the Editorial Director at Separation Science and Chromatography Forum. Aimee brings a broad range of experience in creating, editing, and formatting scientific content. With a degree in medicinal chemistry, a 10-year background in formulation chemistry, an MBA, and a diverse background in publishing, Aimee guides editorial initiatives at Separation Science and Chromatography Forum. Aimee is dedicated to ensuring the delivery of informative, reliable, and practical content to our audience of analytical scientists.

    View Full Profile

Speaker

Here are some related topics that may interest you:

Loading Next Article...
Loading Next Article...