Home / Analytical Training Solutions
Analytical Training Solutions
Analytical Training Solutions, brought to you by Separation Science, is the leading global portal for fundamentals, best practices, troubleshooting and method development training for chromatographic and mass spectrometric techniques.
Comprehensive, self-paced online courses and validated learning provides a unique educational resource for analytical chemists. Currently, we offer HPLC training, LC-MS training, GC training and GC-MS training.
Self-paced Validated Learning
All courses are created by analytical training experts and segmented in a logical way to ensure the most effective educational experience. All course modules are supplemented by quiz questions to validate your learning.
Certificate of Completion
Users can monitor progress via their ‘My Account’ page. Once all the course modules have been viewed and all quiz questions answered correctly, users will be able to download a course completion certificate.
Cost-Effective Learning
Course purchase provides 12 months of unlimited access to expert-developed learning materials, course monitoring and a certificate of completion. Prices range from US$ 189 – US$ 359 per course (except for ‘Interpretation of Mass Spectra’).
Looking for Cost-effective Online Learning in LC & GC?
Does your site have multiple users who would benefit from expert online training in liquid and gas chromatography?
- For a site licence, Analytical Training Solutions provides unlimited access for ALL of your users* to ALL LC and GC courses for a 12-month period.
- All courses are broken down into manageable modules and presented in a logical manner for effective learning.
- Each video module is accompanied by a short quiz to validate your understanding of the materials.
- Upon completion of a course, each user will be able to download a ‘Certificate of Completion’.
For more information complete this form or contact: dean.graimes@sepscience.com.
* Note: all users must be based at the same geographic site.
Liquid Chromatography (LC) Training
Fundamentals of HPLC
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
‘Fundamentals of HPLC’ covers the essentials that every scientist needs in order to make effective use of liquid chromatography instrumentation, including: The basics of the chromatographic process, Terms and definitions of chromatography, How HPLC systems work, Practical tips on preventive maintenance, Principles of separation chemistry, Why “reversed-phase” is the standard separation technique, The meaning of “gradients” and why they are used, How to get the best quantitation and much more. By taking this online course you will acquire a good understanding of the fundamentals of HPLC and get a better knowledge of the key concepts involved. The course is aimed at managers, supervisors, auditors, reviewers, etc. who use information generated by HPLC but do not necessarily do chromatography themselves.
HPLC & UHPLC Troubleshooting
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
'HPLC & UHPLC Troubleshooting: A Performance Qualification Approach' is an intensive online course that teaches you the ins and outs of solving problems that occur with your high-performance liquid chromatography (HPLC) and ultra-high pressure liquid chromatography (UHPLC) methods. You will learn how to qualify the performance of your HPLC or UHPLC using specific tests that also can be used for isolating existing problems. More importantly, you’ll learn how to prevent many of these problems from happening in the first place. This course is designed for anyone who works with HPLC or UHPLC. No previous experience with HPLC or UHPLC systems is assumed; however, much of the course will appeal to the more experienced worker.
Advanced HPLC Method Development using QbD
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
'Advanced HPLC Method Development Using Quality by Design' is an intensive online course that teaches you strategy and technique to develop high-quality HPLC and UHPLC methods quickly and with confidence. You will learn a time-proven technique that walks you through the method development process a step at a time using sound chromatographic principles to help make the process more efficient. The techniques can be used as a stand-alone strategy or added to existing development procedures to help streamline the process. Because the same principles apply to HPLC and UHPLC, you can apply the same information for the development of UHPLC methods. Here’s what the course covers: What Quality by Design (QbD) is and how it applies to HPLC methods?, A review of basic HPLC theory as it applies to method development?, The makeup of HPLC columns including the support material and the bonded phase?, The role of solvents in the separation?, How the column plate number, selectivity, and retention can be used in a logical way to solve even the toughest separation problems?, How to use mobile phase solvents, pH, temperature, chemistry, and other variables to pull apart difficult-to-separate peak pairs?, How gradient elution works and how to remove the mystery of optimizing gradients?, How a scouting gradient can be used to speed the development of both isocratic and gradient methods? How to use a simple spreadsheet calculator to move from the scouting run to the next step in method development?, How computer-assisted method development tools can leverage a small amount of data into a large amount of information about a separation?, How to take advantage of a publicly available internet database to identify equivalent and orthogonal columns?, When standard reversed-phase techniques don’t work, how to choose mixed-mode, ion-pairing, normal phase, HILIC, chiral, or other chromatographic modes?, What’s the same and different when comparing HPLC and UHPLC?, What to look for when validating a method?
Principles of HPLC Validation
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
This class focuses on validating high-performance liquid chromatographic (HPLC) methods developed for the analysis of pharmaceutical drug substance (pure drugs), drug product (formulated drugs), impurities, and degradation products. Although the focus is on pharmaceuticals, the principles apply for most quantitative HPLC methods, such as environmental or general chemical analyses. Here’s what the course covers: What steps are that need to be undertaken during validation?, Why quality is so important?, What basic chromatographic measurements will be used?, Why to approach validation as part of a larger process?, Which regulatory documents are important?, What parameters of the method need to be tested?, What are the different standardization techniques, and when are they used?, What is Quality by Design, and why is it important?, What software tools are available to simplify the process?, What pitfalls should be avoided in validation?, What is pre-validation, and why is it worth my time?, How do I choose a system suitability sample?, How can I tell if the method is out of control?, How much can I adjust a method before I have to re-validate?
HPLC for Biopharmaceuticals
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
Although “small molecule” and “biopolymer” separations have traditionally been considered as separate activities, analysts in the biopharmaceutical industry regularly have to deal with both. Fortunately, the underlying principles of chromatography apply equally well in both situations when interpreted appropriately. 'Practical HPLC for Biopharmaceuticals' explains chromatography in practical terms from the ground up. Here’s what you’ll learn in this online course: The basics of isocratic and gradient HPLC, Reversed-phase and ion exchange HPLC, HPLC equipment – from reservoirs/pumps to tubing/injectors to columns and detectors, Understanding and overcoming common column problems, Alternative modes: normal phase, HILIC and size exclusion, Quantitation, UHPLC, Performance qualification, Troubleshooting and diagnostics.
LC-MS Training
LC-MS/MS for Chromatographers
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
With the introduction of the mass spectrometer (MS) as a practical detector for high-performance liquid chromatography (LC or HPLC), LC-MS began to be used for routine applications. One form of LC-MS uses a tandem MS (LC-MS/MS), that has become the go-to instrument for quantitative analysis of drugs in biological matrices in the pharmaceutical laboratory. As they have become more widely used and understood, LC-MS and LC-MS/MS have found their way into environmental applications, synthetic chemistry, protein analysis, and many other areas. LC-MS/MS has moved from a technique available only to skilled experts in both HPLC and MS to a routine tool usable much as any other HPLC detector. You will find that this introductory course in LC-MS/MS will give you a good foundation of understanding the technique and how to use it in your daily work. We start out with an overview of different MS techniques and focus the majority of the course on the quadrupole mass spectrometer. You will learn how MS works, how ions are produced and fragmented. Sections focus on qualitative, as well as quantitative analysis. Each part of the process, calibration, tuning, sample preparation, HPLC method development, and MS method development are covered. Many tricks and techniques of practical use are presented.
Gas Chromatography (GC) Training
Introduction to GC
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
The ‘Introduction to Gas Chromatography’ online course is a basic introduction to the theory and practice of gas chromatographic analysis. It is designed to bring GC users to a more comfortable and capable level of proficiency in instrument operation, optimization, and troubleshooting. Lessons are presented in a visually engaging and accessible manner through narrated online video presentations. In full recognition of the difficulty in setting large blocks of uninterrupted time for training; the lessons are presented in short segments that can be easily fit into even the busiest schedules. Upon successful completion of the course, trainees will have increased confidence and skills in using gas chromatographs. They will better understand how GC works, be more competent at detecting and diagnosing problems, and will be better at interpreting the quality of analytical results. In the end, trainees will be more capable and comfortable using gas chromatographs.
Intermediate GC
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
The 'Intermediate Gas Chromatography' course is designed for GC users who have a fundamental understanding of how gas chromatography works and who are ready to develop a more in-depth understanding of the technique. As with the ‘Introduction to Gas Chromatography’ course, the ‘Intermediate Gas Chromatography’ course is organized into sections and modules. The sections focus on a given theme and the modular structure underneath exposes students to the information within time-effective sections. Upon successful completion of the course, trainees will have increased knowledge and skills in the development of gas chromatography methods. They will gain an understanding of both qualitative and quantitative methods, as well as expand their skills to encompass areas such as fast GC, and further developing maintenance and troubleshooting abilities.
GC-MS Training
GC-MS for Operators & Developers
Self-paced online course with validated learning and e-certificate of completion
Analytical Training Solutions | Separation Science
‘GC-MS for Operators and Method Developers’ is a specifically designed course for GC users and operators. Fundamental principles, when presented, are done so with a focus on the practical aspects and applications as might be applied on a daily basis. Those who complete this course should be more efficient and comfortable at setting up, troubleshooting, verifying performance, acquiring and interpreting GC-MS data. As with 'Introduction to GC' and 'Intermediate GC' courses, the GC-MS course is organized into chapters and modules. The chapters focus on given themes and the modular structure underneath exposes students to subtopics within time-efficient segments. This course is designed for users of gas chromatographs who are looking to further develop their method development and troubleshooting skills in GC-MS.
Capillary Electrophoresis (CE) Training
Introduction to CE
Self-paced online course with validated learning and certificate of completion
Analytical Training Solutions | Separation Science
If you use capillary electrophoresis (CE) in your work and want a better understanding of the technique, or want to start with CE and want to be well prepared, this course is for you. The course is designed for analytical scientists and technicians who use CE in their regular job, but also lab managers and quality assurance or regulatory people who need to review CE work might find it useful. No previous CE training is assumed, however, much of the course will also appeal to the experienced scientist who wants a firm ground in the basics of CE.